Yes it is working after restart the "HP Management Infrastructure" service i am able to log in EVA
Thanks it was very helpful to me
Yes it is working after restart the "HP Management Infrastructure" service i am able to log in EVA
Thanks it was very helpful to me
How we can calculate speed of data writing through Data protector on to the SAN storage for D2D Backup. I have 16gb Fc connectivity, 6 x 2TB 7.2k HDD's with RAID 5. In addition to the production environment running on same hardware.
Need urgent support.
Regards,
I have some vdisks on a EVA P6350 under the command view we don't see the presentations hosts.
under the utility SSSU we see this hosts. the firmware of storage is XCS1300000 and the version of CV 10.3.3 ;
on others vdisks we see hosts. we reboot the manap and the pb leave.
any suggest please
regards
Hi
The links in this thread no longer work. Do you have any new links that I can try?
Many thanks
Hello,
We have recently moved our EVA4100 unit from one rack to another, including cabling, and since reboot ALL disks are showing "One loop connection lost" (see attached image)
Is this an issue with the disks themselves or the cabling?
I have read that it can be due to one of the following:
1. EVA not being restarted in the correct order
2. Issue with connection on back of EVA
3. Disks needing to be reseated.
Does anyone know of any steps we can follow to resolve this issue?
Kind regards
Hi
as you have moved the EVA from one rack to the other
I would check all cables are seated correctly.
from your options only the second one is possible
If you can I would shutdown the EVA check physicaly all cables are in there
place and corectly in cabled. and power on.
if not just go over all cable connections.
Regards
Good day,
I have a small question, I cannot find the storage space calculator for below config, so hopefully somebody can help me out.
Current configuration:
2x HP Letfhand P4000, 2x HP Lethand P4200:
Currently:
What will happen if I add the next SAN node number 5 (HP Lethand 4300) on the same config, or what will the Utilization be?
Best regards,
Henry van der Leer
Hi Torsten:
Very Thanks your support , but we only have 9.3 cv license , import to 10.3 have some error , this ok?
thanks a lot
Hello Everyone,
I have a HP P6350 controller that is connected to a storageworks D2600 disk enclosure. The enclosure appears in my command view software, but when I try to initialize the disks, it says "Error, drive is unsupported." and all of the drives light up amber.
The controllers are both HSV340 controllers connected via Mini-SAS to the disk enclosure. These controllers are running firmware: 11001100. The drives are all MB2000FBZPN running the latest firmware. They all appear OK and operational before initializing, but display a failed state when attempting to initialize. These drives have been tested and working on other systems.
There are no further errors that the system gives me, so I am a little stuck here. Any help will be much appreciated.
Thanks,
Jamie
Even they look the same, drives for EVA (P6000) and servers are not interchangeable.
P6000 drives are different, they have different firmware. So you cannot use server disks with a P6000.
Hello,
a D2600 disk enclosure is not supported behind an EVA Controller. You need a M6612 enclosure for the P6350 Controller.
The backend looks the same. Please check also the partnumbers of the drives.
Only these drives are supported:
HP M6612 450GB 6G SAS 15K 3.5-inch HDD AP871A
HP M6612 600GB 6G SAS 15K 3.5-inch HDD AP872A
HP M6612 2TB 6G SAS 7.2K 3.5-inch HDD AW590A
HP M6612 3TB 6G SAS 7.2K 3.5-inch HDD (requires XCS 11001000 or later controller firmware) QR479A
HP M6612 4TB 6G SAS 7.2K 3.5-inch HDD (requires XCS 11001000 or later controller firmware) C8R31A
Thomas
HSV450 is an EVA8400. You can use the firmware file, you probably still have it , filename is 450_11300000.sss.
Hi,
I have a problem hsv450 xcs 11300000 controller A battery 2 and 3 , I already changed the batteries and the controller. Continues to exhibit the same problem. Any tips or help ?
The chassis and controller part numbers appear to be the same so what is different between the two? Can I put the D2600 firmware on a enclosure that was originally a M6612? Trying to do the update shows no supported hardware found.
Thanks
What controller would support these drives and this enclosure to create a SAN?
Fibre Channel SAN*
Hi
I have Cage0 (300GB , 15K,FC,SAS) *24 , Cage1 (600GB , 15K,FC,SAS)*24 , can I use CPGS cross this two Cages , have any performance issue ? thanks
From what little you say, it sounds like you started with a 7200c with 24 300GB drives. Then later have added a second cage with 24 600GB drives. Correct?
From a basic performance standpoint, you can have a CPG with all 48 drives in it. With all 48 drives, you will get better performance than with just the original 24. And, unless you have drive pattern filters on your CPGs, they already do use all 48 drives. Hopefully, when the second cage was added, tunesys was run one or more times to distribute what was on the original 24 drives across the 48 drives. Which would have improved the performance of any existing volumes. If not, any volumes created when you had the original 24 300GB drives will still be on just those 24.
What you need to be aware of is, all 48 drives are going to fill fairly evenly. When the 300GB drives fill up, any storage allocation after that time will of course be only on the 600GB drives. Performance on that portion of storage will be reduced compared to any volumes (technically Logical Disks) that are built across all 48 drives.
You can create a CPG that uses just the drives in Cage1. Put any volumes that do not need the improved performance there; this will at least delay the 300GB drives from filling up. For example: createcpg -p -cg 1 -ha mag -t r5 FC_r5_600GB
For each volume you want in the new CPG you will need to:
If you have a Dynamic Optimization license, you can avoid all of that and use tunevv to move volumes into the new CPG with no "down" time.